Products
Home Products Battery Large Production Line Cylindrical Cell Machine

1500 m³/h Cylindrical Battery Line NMP Recovery System

Product Categories

Contact Us

  • Contact Person : Louis Yang
  • Email : Louis@lithmachine.com
  • Address : No. 5 Nanshan Road, Huli District, Xiamen City, Fujian Province, China
1500 m³/h Cylindrical Battery Line NMP Recovery System

1500 m³/h Cylindrical Battery Line NMP Recovery System

  • ItemNo :

    LITH-NMP-1500FL
  • MOQ :

    1
  • Compliance:

    CE
  • Warranty:

    2 years
  • Delivery Time:

    5 days
  • Email :

    Louis@lithmachine.com
  • Product Details

1500 m³/h Cylindrical Battery Line NMP Recovery System




I. System Function

This series of NMP recovery systems leverages the miscibility of NMP and water to treat and recover exhaust gases emitted from coating machines. The system is fully automated to maintain stable NMP concentration and TVOC levels in the exhaust air. Designed as an integrated system, it ensures operational stability and safety, while meeting national and local environmental protection standards. The system includes: spray tower, pump group, blower, ventilation ducts, and electrical control system. With a high recovery rate, low operating costs, compact and aesthetic structure, and excellent performance, it is easy to operate and ideal for coating processes in lithium battery laboratory production lines.

 

II. System Configuration

1. Air Volume Handling Capacity: 1500 m³/h, Model LITH-NMP-1500FL;
Complies with the emission limits for total non-methane hydrocarbons under GB 30484-2013 Emission Standard of Pollutants for Battery Industry.

 

2. Main Unit Color: SUS gray.

3. Functional Modules Overview:

No.

Module

Description

1

Spray Tower

Recovers NMP vapors through water washing and ensures emission compliance.

2

Pump Group

Circulates water within the tower and discharges liquids.

3

Blower

Supplies air to the tower and maintains positive pressure in the coater.

4

Ventilation Duct

Connects the coating machine exhaust port to the recovery tower.

5

Control System

Realizes automation between the recovery system and the coating machine.

 

IV. Design Basis and Standards

Design Principles:

1. Compliant with national, industrial, and local regulations as well as customer requirements; ensures the treated exhaust meets all applicable standards.

2. Adopts efficient, energy-saving, and easy-to-implement processes with goals of low energy consumption, low investment, minimal footprint, and simplified maintenance.

3. Utilizes branded, high-quality equipment and components for reliability.

4. Ensures no secondary pollution is generated during installation or operation.

 

V. System Design Parameters

Parameter

Specification

Recovery System Model

LITH-NMP-1500FL

Max Exhaust Treatment Capacity

2000 m³/h

Equipment Dimensions

1.6m (L) × 1.2m (W) × 1.6m (H)

Material

SUS304

Power Supply

380V / 3 Phase / 50Hz

Installed Power

3KW (1.5KW circulation pump + 1.5KW fan)

Operating Weight

0.48 tons

Solvent Recovery Rate

≥ 90%

NMP Recovered Liquid Concentration

≥ 80%

Tail Gas Emission Concentration

≤ 50 mg/m³

Water Evaporation Rate

≤ 0.015 m³/h

 

VI. System Image and Working Principle (Images for reference only)

1. Equipment Image: 


2. Working Principle:
The system recovers NMP from exhaust gases through soft water absorption. Waste gas enters from the bottom of the tower and passes through the adsorption unit, where NMP dissolves into water and steam. The treated gas then passes through a gas-liquid separator and a top spray rinsing unit to ensure complete NMP absorption. Due to the high temperature of incoming gas, energy exchange causes partial water evaporation. The system uses a circulation pump to recycle tower liquid through the adsorption unit, optimizing heat exchange and minimizing water waste while improving the NMP concentration in the recovered liquid. Treated exhaust gas can be discharged directly without further treatment, effectively achieving near-zero emissions.

 

VII. Control System

1. Electrical Panel Components:

No.

Component

Model

Qty

Manufacturer

1

Air Switch

4P/60A

1

Chint

2

Single-Pole Switch

1P/10A

2

Chint

3

Frequency Inverter

1.5KW

1

V&T

4

AC Contactor

1210, 2510

5

Chint

5

Thermal Overload Relay

4A / 13A

4

Chint

6

Indicator Lights

Red, Green

2

Chint

7

Selector Switch

NP2

2

Chint

8

Fuse

6A

1 set

Chint

9

Time Relay

40n

1

Chint

10

Temperature Controller

18/H

2

Chint

11

Alarm Light

Ad16-22sm

1

Chint

12

Control Cabinet

500×400×200 / 400×400×150

1 each

Chint

 

2. Control System Description:

No.

Item

Specification / Remarks

1

Main Control Unit

Independent outdoor protection cabinet; separate strong/weak current layout; remote start/stop from coater; button interface.

2

Operation Modes

Manual, automatic, emergency stop, and remote start/stop.

3

Alarms

Equipment fault alarm via sound-light at coater head and buzzer alarm in outdoor cabinet.

4

Safety Features

Mechanical and electrical interlocks, self-locking, sensor protection, temperature anomaly alarms, and power-off protection.






NMP Solvent Recovery System


NMP Solvent Recovery System

cylindrical cell production line









PACKAGE:

  1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

  2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

  3 Responsible for the damage during the shipping process, will change the damaged part for you for free.

 

DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to 

production season and order quantity.