ItemNo :
LITH-CT-4008-5V200AMOQ :
1Place of Origin:
ChinaColor :
optionalPort :
Xiamen PortCompliance:
CEWarranty:
2 yearsDelivery Time:
5 days
Technical parameters
|
Project index |
Parameter index |
|||
|
Input Power |
AC 480V± 10% / 50Hz Three Phase |
|||
|
resolution |
AD:16bit;DA:16bit |
|||
|
Input Resistance |
≥ 1MΩ |
|||
|
Input Power |
14177W |
|||
|
Channel Features |
Constant Current Source and Constant Voltage Source withIndependent pairs of Closed-loop Structure |
|||
|
Channel Control Mode |
Independent Control |
|||
|
Voltage |
Per Channel Voltage Range |
25mV~5V |
||
|
Discharge Min Voltage |
0V |
|||
|
Accuracy |
± 0.1% ofFS |
|||
|
Stability |
± 0.1% ofFS |
|||
|
Current |
Per Channel Current Range |
1A~200A |
||
|
Stop Current |
0.4A |
|||
|
Accuracy |
± 0.1% ofFS |
|||
|
Stability |
± 0.1% ofFS |
|||
|
Power |
Per Channel Output Power |
1000W |
||
|
Stability |
± 0.2% ofFS |
|||
|
Time |
Current Response Time |
20ms (0-FullRange) |
||
|
Step Time Range |
≤(365*24 )hour/step, Time Form Support 00:00:00(h、min:s、ms) |
|||
|
Data Recording |
Record Condition |
Time△T:100mS |
||
|
Voltage△U:10mV |
||||
|
Current△I:400mA |
||||
|
Record Frequency |
10Hz |
|||
|
Charge |
Charge Mode |
Constant Current Charge、Constant Voltage Charge、 Constant Current and Constant Voltage Charge、CPC |
||
|
End Conditon |
Voltage、Current、Relative Time、Capacity、-△V |
|||
|
Discharge |
Discharge Mode |
CCD、CPD、CRD |
||
|
End Condition |
Voltage、Current、Relative Time、Capacity |
|||
|
Pulse |
charge |
CCC、CPC |
||
|
Discharge |
CCD、CPD |
|||
|
Min Pulse Width |
500ms |
|||
|
Automated Switch |
Automated swith from chargeto discharge for each pulse |
|||
|
End Condition |
Voltage, Test Time |
|||
|
AUX Channel |
Temperature Range |
-25C~ 110C |
||
|
Temperature accuracy |
±1C |
|||
|
Temperature Resolution |
0.1C |
|||
|
Cycle |
Loop Measure Range |
1~65535times |
||
|
Max Steps Per Loop |
254 |
|||
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|||
|
Protection |
Software Protection |
|
||
|
|
||||
|
Voltage limit、Low Current limit、Upper Current limit、Delay Time |
||||
|
Hardware Protection |
Have Anti-reverse Protection Function |
|||
|
Voltage and Current Testing Sample |
4-wire connecting |
|||
|
Noise |
<85dB |
|||
|
Database |
MySQL Database |
|||
|
A Means ofCommunication ofUpper Machine |
TCP/IP Protocol |
|||
|
Data Output |
EXCEL2003/2010、TXT |
|||
|
Communication Interface |
Ethernet Port |
|||
|
Per UnitMain Channels No. |
8 |
|||
|
Dimensions |
36U27",860*600*1780(mm) |
|||
|
Working Temperature Range |
0℃~40℃ |
|||
|
Storage Temperature Range |
-10℃~50℃ |
|||
|
Working Environment Relative Humidity Range |
30% ~ 80% RH |
|||
|
Storage Environment Relative Humidity Range |
30% ~ 90% RH |
|||
![]()
![]()
![]()

![]()
PACKAGE:
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damaged part for you for free.
DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to
production season and order quantity.

ONLINE
+86 13174506016
Louis@lithmachine.com
+86 18659217588